Skip to main content
Application Notes

Monitoring Hospital Non‑Critical Spaces

Enhancing Safety and Compliance

By incorporating Setra's room monitoring solutions, hospitals can proactively address compliance issues in non-critical spaces (such as linen storage, emergency departments, Bronchoscopy Spaces, etc.), ensuring patient safety, staff well-being, and regulatory adherence. Regular monitoring with Setra's reliable and user-friendly solutions minimizes the risk of non-compliance surprises and supports hospitals in achieving successful audits and inspections. This is why Setra's room monitors are trusted by the top 6 cardiology and heart surgery hospitals across the nation.

Linen-Closet-NH---Isometric


Critical Space

DP to Adjacent Space*


Min DP (in WC)


DP Continuous Monitoring

Temp. (°F)

RH(%)

ACH

Bronchoscopy

(-)

0.01

Best Practice

68 - 73

Not Specified

12

Morgue/Autopsy

(-)

0.01

Best Practice

68 - 73

Not Specified

12

Dirty Linen Storage

(-)

Not Specified

Best Practice

Not Specified

Not Specified

10

Clean Linen Storage

(+)

Not Specified

Best Practice

72 - 78

Not Specified

2

Emergency Department - Non-trauma

(-)

Not Specified

Best Practice

70 - 75

Max 65

12

Emergency Department Trauma

(+)

Not Specified

Best Practice

70 - 75

20 - 60

15


*Based off of ASHRAE 170 Standards

Proactive Monitoring:

By implementing the Setra Lite, it ensures that non-critical hospital spaces have adequate ventilation and air quality, reducing the risk of infection and promoting overall health and well-being for patients, staff, and visitors. By directing airflows correctly, it proactively prevents cross-contamination and the entry of infectious pathogens into critical areas like operating spaces and isolation spaces. Moreover, the LITE's automated monitoring eliminates the need for manual air quality checks, saving both time and money for staff.

Preventing Audit Surprises:


Without proper monitoring, hospitals may unknowingly fall out of compliance in non-critical spaces, only realizing the issue during audits or inspections. Setra's room monitoring solutions, such as the Flex and Lite models, provide easy-to-see information and visual indications of potential problems. This enables healthcare professionals to proactively address any non-compliant conditions and avoid last-minute surprises during audits.

Simplifying Joint Commission Inspections:

Joint Commission inspections can be complex and demanding, requiring hospitals to demonstrate adherence to strict standards. Setra's monitoring solutions streamline this process by providing clear, easily interpretable data on the Flex and visual indications on the Lite. These features enable hospitals to showcase their commitment to safety and compliance, facilitating a smoother inspection experience.

Other Spaces Setra Covers:

Compounding Pharmacies
Hospital Operating Spaces
Protected Environment Spaces
Noncritical Spaces

Product Links:

Flex
SRH1
SPC8000
SRH200
Lite

Monitoring Hospital Non‑Critical Spaces